- Manueller Pulscheck ungenau, Studien unter HLM bei Bypass 15-75% von Fachpersonal12, 10s oft überschritten initial und bei pulse checks
- Besser zur Entscheidung CPR j/n:
Footnotes
-
Tibballs. Resuscitation 2010. The influence of time on the accuracy of healthcare personnel to diagnose paediatric cardiac arrest by pulse palpation ↩
-
Eberle. Resuscitation 1996. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. In 10% (6/59), an absent carotid pulse was not recognized as pulselessness. In 45% (66/147), a pulse was not identified despite a carotid pulse with a systolic pressure > or = 80 mmHg. Only 1/59 (2%) identified pulselessness correctly within 10 s. ↩