• Manueller Pulscheck ungenau, Studien unter HLM bei Bypass 15-75% von Fachpersonal12, 10s oft überschritten initial und bei pulse checks
  • Besser zur Entscheidung CPR j/n:

Footnotes

  1. Tibballs. Resuscitation 2010. The influence of time on the accuracy of healthcare personnel to diagnose paediatric cardiac arrest by pulse palpation

  2. Eberle. Resuscitation 1996. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. In 10% (6/59), an absent carotid pulse was not recognized as pulselessness. In 45% (66/147), a pulse was not identified despite a carotid pulse with a systolic pressure > or = 80 mmHg. Only 1/59 (2%) identified pulselessness correctly within 10 s.